Overview
TS-3 temperature sensor
TS-3 temperature sensor
1
Overview
The TS-3 temperature sensor provides an input signal for temperat
ure compensation of specific Siemens ultrasonic level controllers.
Benefits
•
Chemically resistant ETFE enclosure
•
Fast response time
•
Approved for use in potentially explosive atmospheres
Application
Temperature compensation is essential in applications where tem
perature variations of the sound medium are expected.
By installing the temperature sensor close to the sound path of the
associated ultrasonic transducer, a signal representative of the
sound medium’s ambient temperature is obtained. The temperature
sensor should not be mounted in direct sunlight.
The TS-3 is used in conjunction with ultrasonic transducers that do
not have an integral temperature sensor. It is also recommended in
cases where the integral temperature sensor of the transducer can
not be used.
The following conditions are typical for use of the TS-3 sensor:
where a fast reaction to temperature variations is required, where a
flanged ultrasonic transducer is used, or where high temperatures
are encountered.
The TS-3 is not compatible with devices using the TS-2 or LTS-1
temperature sensors. Refer to the associated controller manual for
more details.
•
Key Applications: for use in applications where temperature
sensor measurement from transducer does not accurately repres
ent vessel temperature. Used for applications requiring quick tem
perature response (open channel monitoring).
Design
Conduit (supplied by others)
Coupling (supplied by others)
Plate or wall
Flange or wall
Locknut (supplied by others)
Note: Clearance hole/
locknut Installation
method is not suitable
for pressure applications.
Clearance
Tapped
TS-3
TS-3 temperature sensor
TS-3 Temperature sensor ·
5/2024