4/234
Siemens FI 01 · 2021
Level measurement
Continuous level measurement
Radar level transmitters
SITRANS Probe LR
■
Selection and ordering data Article No. Order code
SITRANS Probe LR Radar level transmitter
Continuous, non-contact, 20 m (66 ft) range,
for liquids and slurries.
7ML5430-
7 7 7 7 0
Click on the Article No. for the online
configuration in the PIA Life Cycle Portal.
Enclosure/Cable inlet
Plastic, (PBT), 2 x ½" NPT 1
Plastic, (PBT), 2 x M20 x 1.5 2
Antenna type/Material - (max. 3 bar and 80 °C)
Polypropylene antenna
1½" NPT [(Taper), ANSI/ASME B1.20.1],
comes with integral 100 mm shield
A
R 1½" [(BSPT), EN 10226],
comes with integral 100 mm shield
B
G 1½" [(BSPP), EN ISO 228-1],
comes with integral 100 mm shield
C
1½" NPT [(Taper), ANSI/ASME B1.20.1],
comes with integral 250 mm shield
D
R 1½" [(BSPT), EN 10226],
comes with integral 250 mm shield
E
G 1½" [(BSPP), EN ISO 228-1],
comes with integral 250 mm shield
F
Approvals
General Purpose, CE, RED, RCM A
General Purpose, CSA
us/c
, FM, FCC B
CSA Class I, Div. 1, Groups A, B, C, D, Class II,
Div. 1, Group G, Class III, FCC, Intrinsically Safe
C
FM, Class I, II and III, Div. 1,
GroupsA,B,C,D,E,F,G, FCC, IntrinsicallySafe
D
IECEx Ex ia IIC T4; ATEX II 1G EEx ia IIC T4, RED,
RCM, Intrinsically Safe; INMETRO Ex ia IIC T4 Ga;
EAC
E
Communication/Output
4 ... 20 mA, HART 1
Further designs
Please add "-Z" to Article No.
and specify Order code(s).
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]:
Measuring-point number/identification
(max. 27 characters) specify in plain text
Y15
Manufacturer's test certificate:M to DIN 55350,
Part 18 and to ISO 9000
C11
Operating Instructions
All literature is available to download for free, in a
range of languages, at
http://www.siemens.com/processinstrumentation/documentation
Accessories Article No.
Handheld programmer, Intrinsically Safe,
ATEX II 1G, Ex ia
7ML5830-2AH
HART modem/USB
(for use with a PC and SIMATIC PDM)
7MF4997-1DB
One metallic cable gland M20 x 1.5,
rated -40 ... +80 °C (-40 ... +176 °F)
7ML1930-1AP
SITRANS RD100, loop powered display -
see Chapter 7
7ML5741-.....-.
SITRANS RD150, remote digital display for
4 ... 20 mA and HART devices - see Chapter 7
7ML5742-.....-....
SITRANS RD200, universal input display with
Modbus conversion - see Chapter 7
7ML5740-.....-..
SITRANS RD300, dual line display with totalizer
and linearization curve and Modbus conversion -
see Chapter 7
7ML5744-.....-..
For applicable back up point level switch -
see point level measurement section
Spare parts
Plastic lid 7ML1830-1KB
For applicable back up point level switch -
see point level measurement section
© Siemens 2020