Flow sensors
Overview
SITRANS FMS500
SITRANS FMS500
3/88
Overview
The SITRANSFMS500 is a magnetic flow meter sensor suitable for
volume flow measurement of liquids (conductive) and is the ideal
product for applications in water abstraction, wastewater treatment,
water distribution networks, and irrigation.
The rugged, fully welded design supports direct burial, constant
flooding and to stand up a wide range of harsh chemicals found in
water-based applications in many different industries.
Designed for highly accurate measurement in low-flow conditions,
these meters can measure from very low velocities up to 10m/s, giv
ing it a very wide measurement range.
Combined with a flow meter transmitter it is a traditional externally
powered electromagnetic flow meter system
Benefits
Zero Up and Zero Down installation capabilities
NBR rubber liner for all water and wastewater applications
EPDM liner specifically for drinking water applications requiring
special approvals
Soft elastomer facing provides high abrasion resistance
Increased low flow accuracy for water leak detection
Rugged construction with no moving parts for maintenance-free
operation over many years.
Simple on-site upgrade to IP68 of a standard sensor allowing
underground installation, permanent immersion or underwater
installation
Integrated grounding electrodes – no grounding rings required for
many applications
Short delivery time
Built-in length according to ISO20456 (up to DN400mm)
SENSORPROM™Technology provides an automatic upload of start-
up settings and calibration data for easy commissioning
Designed to allow in-situ verification for easy performance check
In conformity with ISO4064, OIMLR49 and EN14154
Application
The SITRANSFMS500 with its NBR or EPDM soft rubber lining is a
flow meter sensor for all kinds of water applications such as ground
water, potable water, cooling water, wastewater, sewage, or sludge
applications.
Connected to the compatible transmitter SITRANSFMT020, either
mounted remotely or as a compact unit, it forms the magnetic flow
meter system SITRANSFM520 which can be used in almost all gen
eral-purpose water applications.
SITRANSFM520
Perfect match for a cost-effective solution for all water and wastewa
ter applications. Measuring accuracy ±0.4% of flow rate, optional
±0.2% of flow rate available.
Siemens FI 01 · 2024
Flow sensors
SITRANS FM (electromagnetic)
© Siemens AG 2024
News 02/2024
Flow sensors
SITRANS FMS500
3/89
Selection and ordering data
Article No.
Sensor SITRANS FMS500
7ME653-
- - 2 A
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
Transmitter variant
No transmitter (sensor only) 0
Transmitter SITRANS FMT020 2
Diameter
DN 15, 1/2 inch 1 V
DN 25, 1 inch 2 D
DN 40, 1 1/2 inch 2 R
DN 50, 2 inch 2 Y
DN 65, 2 1/2 inch 3 F
DN 80, 3 inch 3 M
DN 100, 4 inch 3 T
DN 125, 5 inch 4 B
DN 150, 6 inch 4 H
DN 200, 8 inch 4 P
DN 250, 10 inch 4 V
DN 300, 12 inch 5 B
DN 350, 14 inch 5 D
DN 400, 16 inch 5 H
DN 450, 18 inch 5 K
DN 500, 20 inch 5 R
DN 600, 24 inch 5 Y
DN 700, 28 inch 6 B
DN 750, 30 inch 6 D
DN 800, 32 inch 6 H
DN 900, 36 inch 6 K
DN 1000, 40 inch 6 R
DN1050, 42 inch 6 Y
DN1100, 44 inch 7 D
DN1200, 48 inch 7 H
Process connection
EN 1092-1 PN 10 flanges B
EN 1092-1 PN 16 flanges C
EN 1092-1 PN16 flanges, non-PED version D
ANSI B16.5 Class 150 flanges J
AWWA C-207 Class D flanges M
AS 4087 PN 16 flanges S
Process connection material
Carbon steel ASTM A 105 with corrosion-resistant coating acc. to ENISO12944 grade C4 0
Carbon steel ASTM A 105 with corrosion-resistant coating acc. to ENISO12944 grade C5 (300μm) 1
Liner material
EPDM (soft rubber) 2
NBR (soft rubber) 3
Electrode material
Hastelloy C276 / 2.4819 2
Transmitter mounting & enclosure type
No transmitter (sensor only) A
Compact design (integral mount), plastic enclosure G
Remote design, plastic enclosure (wall-mounting unit and sensor terminal board included) J
Power supply
None (sensor only) 0
24VDC 2
100…240VAC, 50/60 Hz 3
Siemens FI 01 · 2024
SITRANS FM (electromagnetic)
© Siemens AG 2024
News 02/2024
Flow sensors
SITRANS FMS500
3/90
Selection and ordering data (continued)
Additional information Order code
Please add "-Z" to Article No. and specify
Order code(s) and plain text.
Cable glands
Without cable glands (blind plugs) A00
M20x1.5 cable glands, material polyamide A02
1/2 inch NPT cable glands, material
polyamide
A05
Certificates
Declaration of compliance with the order
2.1 (EN 10204)
C00
Inspection certificate 3.1 (EN 10204) -
Material of pressure-containing and wetted
parts
C12
Test report 2.2 (EN 10204) C14
Inspection certificate 3.1(EN 10204) -
Pressure test
C18
High accuracy calibration
High accuracy factory calibration 0.2%,
DN≤200, ≤8inch
D01
High accuracy factory calibration 0.2%,
DN250…600, 10…24inch
D02
High accuracy factory calibration 0.2%,
DN700…1200, 28…48inch
D03
5-point calibration
5-point factory calibration, DN≤200,
≤8inch
D10
5-point factory calibration, DN250…600,
10…24inch
D11
5-point factory calibration, DN700…1200,
28…48inch
D12
10-point calibration
10-point factory calibration, DN≤200,
≤8inch
D15
10-point factory calibration, DN250…600,
10…24inch
D16
10-point factory calibration,
DN700…1200, 28…48inch
D17
Default matched-pair calibration
Default matched-pair factory calibration,
DN≤200, ≤8inch
D20
Default matched-pair factory calibration,
DN250…600, 10…24inch
D21
Default matched-pair factory calibration,
DN700…1200, 28…48inch
D22
5-point matched-pair calibration
5-point, matched-pair factory calibration,
DN≤200, ≤8inch
D25
5-point, matched-pair factory calibration,
DN250…600, 10…24inch
D26
5-point, matched-pair factory calibration,
DN700…1200, 28…48inch
D27
10-point matched-pair calibration
10-point, matched-pair factory calibration,
DN≤200, ≤8inch
D30
10-point, matched-pair factory calibration,
DN250…600, 10…24inch
D31
10-point, matched-pair factory calibration,
DN700…1200, 28…48inch
D32
Accredited ISO/IEC 17025 calibration
ISO/IEC17025 accredited, 5-point, matched-
pair factory calibration, DN≤200, ≤8inch
D35
ISO/IEC17025 accredited, 5-point, matched-
pair factory calibration, DN250…600,
10…24inch
D36
ISO/IEC17025 accredited, 5-point, matched-
pair factory calibration, DN700…1200,
28…48inch
D37
General safety
CSA General Purpose E06
Additional information Order code
Country of origin
France E90
Communication
HART with 4…20mA output, active or
passive
F01
Modbus RTU / RS485 F04
PROFINET F07
EtherNet/IP F09
Device options
Sensor terminal board factory mounted J00
Sensor cables factory mounted J01
Factory preconfigured for transmitter
mounting in compact design (integral
mount)
J02
Type of protection (IP)
IP68 (NEMA6P) protection class for sensor
in remote design, without potting (to 2m
depth, 10days)
L50
IP68 (NEMA6P) protection class for sensor
in remote design, factory potted (to 10m
depth, continuously)
L51
Sensor cables
Cable kit with coil and electrode cable,
standard type (3×1.5mm
2
), PVC-jacket
5m (16ft) T00
10m (33ft) T01
20 m (65 ft) T03
30 m (98 ft) T05
40 m (131 ft) T06
50 m (164 ft) T07
60 m (197 ft) T08
100 m (328 ft) T11
150 m (492 ft) T14
200 m (656 ft) T16
500 m (1640 ft) T18
Cable kit with coil cable standard type
(3×1.5mm
2
) and electrode cable special
type (3×0.25mm
2
), PVC-jacket
5 m (16 ft) T50
10 m (33 ft) T51
15 m (49 ft) T52
20 m (65 ft) T53
25 m (82 ft) T54
30 m (98 ft) T55
40 m (131 ft) T56
50 m (164 ft) T57
60 m (197 ft) T58
100 m (328 ft) T61
150 m (492 ft) T64
200 m (656 ft) T66
500 m (1640 ft) T68
Device settings
Measuring range: Upper range value (Q
max
),
unit
Y01
Current output damping Y02
Current output signal range Y03
Low flow cut off Y04
Flow direction (Default setting: Positive) Y05
Siemens FI 01 · 2024
SITRANS FM (electromagnetic)
© Siemens AG 2024
News 02/2024
Flow sensors
SITRANS FMS500
3/91
Selection and ordering data (continued)
Additional information Order code
Empty pipe detection (Default setting: On) Y06
Mains frequency (Default setting: 50Hz) Y07
Operation language display (default setting
English)
Y24
Device identification
Location designation (TAG), device
parameter and stainless-steel plate for
transmitter (max.32characters)
Y11
Measuring point description, device
parameter and stainless-steel plate for
transmitter (max.32characters)
Y12
Location designation (TAG), device
parameter and adhesive label for
transmitter (max.32characters)
Y13
Measuring point description, device
parameter and adhesive label for
transmitter (max.32characters)
Y14
Location designation (TAG), device
parameter and stainless-steel plate
(max.32characters)
Y15
Measuring point description, device
parameter and stainless-steel plate
(max.32characters)
Y16
Location designation (TAG), device
parameter and adhesive label
(max.32characters)
Y18
Measuring point description, device
parameter and adhesive label
(max.32characters)
Y19
Additional information Order code
Totalizer 1 settings
Preset value Y30
Unit Y31
Direction Y32
Failure mode Y33
Decimal point Y34
Totalizer 2 settings
Preset value Y35
Unit Y36
Direction Y37
Failure mode Y38
Decimal point Y39
Totalizer 3 settings
Preset value Y40
Unit Y41
Direction Y42
Failure mode Y43
Decimal point Y44
Pulse output settings
Volume per pulse Y50
Pulse width Y51
Siemens FI 01 · 2024
SITRANS FM (electromagnetic)
© Siemens AG 2024
News 02/2024
Flow sensors
SITRANS FMS500
3/92
Technical specifications
SITRANSFMS500 flowmeter sensor
Product characteristic For demanding applications in the water & wastewater industry
Measurement of Volume flow, flow velocity, electrical conductivity
Nominal diameter Coned sensor (octagon liner): DN15...40 (½"...1½")
Coned sensor: DN50...300 (2”...12”)
Full bore sensor: DN350...1200 (14”...48”)
Mode of operation
Measuring principle Electromagnetic induction
Medium conductivity Liquids with an electrical conductivity ≥5μS/cm.
Excitation frequency
(mains supply: 50Hz / 60Hz)
DN15...65 (1/2"...2 1/2"): 12.5Hz / 15Hz
DN80...150 (3”...6”): 6.25Hz / 7.5Hz
DN200...300 (8”...12”): 3.125Hz / 3.75Hz
DN350...1200 (14”...48”): 1.5625Hz / 1.875Hz
Process connection
Flanges
1)
EN1092-1 PN10 (145psi) Flat face DN200...300 (8"...12")
PN10 (145psi) Raised face DN350...1200 (14"...48")
PN16 (232psi) Flat face DN50...300 (2"...12")
PN16 (232psi) Raised face DN350...1200 (14"...48")
PN40 (580psi) Flat face DN15...40 (½"...1½")
ANSIB16.5 Class 150 Flat face ½"...12”
Class 150 Raised face 14"...24”
AWWAC-207 ClassD Flat face 28...48"
AS/NZS 4087 PN16(232 psi) Flat Face DN50...300 (2"...12")
PN16(232 psi) Raised face DN350...1200 (14"...48")
JISB2220:2004 10K DN 15 ...600 (1"...24")
Rated operating conditions
Ambient temperature
Sensor -20...+70°C (-40...+158°F)
Compact with transmitter -20 ... +65 °C (-40 ... +149 °F)
Operating pressure (abs)
(maximum operating pressure depending on flange
type)
DN15...40 (1/2"...1 1/2"): 0.01...40bar (0.15...580psi)
DN50...300 (2"...12"): 0.03...20bar (0.44...290psi)
DN350...1200 (14"...48"): 0.01...16bar (0.15...232psi)
Protection class
Standard IP66/67, NEMA 4X/6
Optional IP68 and NEMA 6P (2m, 10 days) for sensor in remote design
IP68 and NEMA 6P (10m, continuously) for sensor in remote design
Mechanical load (vibration)
Integral mount / compact version Vibration, sinusoidal according to IEC 60068-2-6
2...4 Hz, 3.5 mm peak
8.4...500 Hz, 1 g peak
Vibration broad-band random, according to IEC 60068-2-64
10...200 Hz, 0.003 g2/Hz
200...500 Hz, 0.001 g2/Hz
Total: 1.54 g rms
Vibration, sinusoidal according to IEC 60068-2-6
Sensor
2...8.4 Hz, 7.5 mm peak
8.4...500 Hz, 2 g peak
Transmitter
2...8.4 Hz, 1.5 mm peak
8.4...500 Hz, 0.7 g peak
Vibration broad-band random, according to IEC 60068-2 64
Remote version
Sensor
10...200 Hz, 0.01 g2/Hz
200...500 Hz, 0.003 g2/Hz
Total: 1.54 g rms
Transmitter
10...200 Hz, 0.003 g2/Hz
200...500 Hz, 0.001 g2/Hz
Total: 1.54 g rms
Process temperature
Siemens FI 01 · 2024
SITRANS FM (electromagnetic)
© Siemens AG 2024
News 02/2024
Flow sensors
SITRANS FMS500
3/93
Technical specifications (continued)
SITRANSFMS500 flowmeter sensor
NBR liner -10...+70°C (14...158°F)
EPDM liner -10...+70°C (14...158°F)
Pressure drop DN15 and 25 (½" and 1"): Max.20mbar (0.29psi) at 1m/s (3ft/s)
DN40...300 (1½"...12"): Max.25mbar (0.36psi) at 3m/s (10ft/s)
DN350...1200 (14"...48"): Insignificant
Test pressure 1.5×PN (where applicable)
Design
Dimensions See dimensional drawings
Weight See dimensional drawings
Material
Housing and flanges Carbon steel ASTMA 105 with corrosion resistant coating of class C4 or C5 (durability up to 15 years)
ENISO12944
Measuring electrode HastelloyC276 / 2.4819
Grounding electrode HastelloyC276 / 2.4819
Measuring pipe
2)
Stainless steel AISI304 / 1.4301
Terminal box Polycarbonate
Cable entries 4 x metric thread (size M20 x 1.5)
Pressure equipment Conforming with 97/23 EC
Electromagnetic compatibility Conforming with 2004/108/EC
Calibration
Standard Zero-point, 2×25% and 2×90%
Optional 5-point calibration: 20 %, 40%, 60%, 80%, 100% of factory Qmax
10-point calibration: ascending and descending at 20%, 40%, 60%, 80%, 100% of factory Qmax
Matched pair calibration: default, 5-point or 10-point
ISO/IEC 17025 accredited, 5-point, matched-pair calibration
Certificates and approvals
General purpose CE (LVD, PED, EMC, RoHS), UKCA
Drinking water WRAS (WRc, BS 6920 material approval for cold water, GB)
NSF/ANSI Standard 61 (Cold water, US)
ACS listed (France)
DVGW W270 (Germany)
Belgaqua (Belgium)
AS/NZS 4020 (Australia/New Zealand)
GB/T 5750 (China)
Others Environmental Product Declaration (EPD)
EAC (Kazakhstan)
1)
DN750, DN1050 and DN1100 (30", 42" and 44") not available with EN 1092-1 (PN 10 and PN 16) and AS 4087 flanges
2)
DN>300 (12”)
Siemens FI 01 · 2024
SITRANS FM (electromagnetic)
© Siemens AG 2024
News 02/2024
Flow sensors
SITRANS FMS500
3/94
Dimensional drawings
153.6 (6.05)
104 (4.1)
A
L
D1
153.6 (6.05)
104 (4.1)
A
D1
L
153.6 (6.05)
104 (4.1)
A
D1
L
SITRANSFMS500 Sensor: version 7ME6530 DN15…40 (½"...1½") (left), version 7ME6530 DN50…300 (2”…12”) (middle) and version 7ME6530
DN350…1200 (14”…48”) (right)
Sensor SITRANS FMS500 (7ME653)
Nominal diameter A D1 L1) Weight
2)
[mm] [inch] [mm] [inch] [mm] [inch] [mm] [inch] [kg] [lbs]
15 ½ 170 6.7 77 3.0 200 7.9 5 11
25 1 180 7.1 96 3.8 200 7.9 6 13
40 195 7.7 127 5.0 200 7.9 9 20
50 2 181 7.1 76 3.0 200 7.9 10 22
65 187 7.4 89 3.5 200 7.9 12 26
80 3 193 7.6 102 4.0 200 7.9 13 29
100 4 200 7.9 114 4.5 250 9.8 17 37
125 5 210 8.3 140 5.5 250 9.8 20 44
150 6 225 8.9 168 6.6 300 11.8 27 60
200 8 250 9.8 219 8.6 350 13.8 39 86
250 10 277 10.9 273 10.8 450 17.7 56 123
300 12 303 11.9 324 12.8 500 19.7 72 159
350 14 375 14.8 451 17.8 550 21.7 115 254
400 16 400 15.7 502 19.8 600 23.6 143 315
450 18 431 17.0 563 22.2 600 23.6 177 390
500 20 456 18.0 614 24.2 600 23.6 222 489
600 24 507 20.0 715 28.2 600 23.6 321 708
700 28 557 21.9 816 32.1 700 27.6 331 730
750 30 584 23.0 869 34.2 750 29.5 - -
800 32 609 24.0 927 36.5 800 31.5 386 851
900 36 656 25.8 1032 40.6 900 35.4 482 1063
1000 40 707 27.8 1136 44.7 1000 39.4 672 1482
1050 42 707 27.8 1136 44.7 1000 39.4 - -
1100 44 758 29.8 1238 48.7 1100 43.3 - -
1200 48 813 32.0 1348 53.1 1200 47.2 1116 2460
1)
Tolerances on built-in length: DN15...200 (½"...8"): +0/-3mm (+0/-0.12"), DN250...400 (10"...16"): +0/-5 mm (+0/-0.20"), DN450...600 (18"...24"):
+5/-5mm (+0.20/-0.20"), DN700...1200 (28"...48"): +10/-10mm (+0.39/-0.39")
2)
Weights in kg/lbs are for PN40 DN≤40, PN16 DN>40 without transmitter. With transmitter FMT020 installed, weight is increased by approximately 1.0kg
(2.2lb).
Siemens FI 01 · 2024
SITRANS FM (electromagnetic)
© Siemens AG 2024
News 02/2024